Select Bandwidth
350 MHz - 2 GHz
2.5 GHz - 10 GHz
11 GHz - 100 GHz
Enter your email address below and we'll send you an email with 's information and line list attached.
Name:
Email:
  

Oscilloscopes

Teledyne LeCroy WaveMaster 8 Zi-A 4GHz-30GHz Oscilloscopes
 
Product Overview

WaveMaster 8 Zi-A combines the highest bandwidth (45 GHz) and sample rate (120 GS/s) with superior signal fidelity performance and 20 GHz on all four input channels. Models are available from 4 to 45 GHz with complete bandwidth upgradability throughout the range. The X-Stream II architecture maximizes speed in all aspects and provides for full analysis on maximum record lengths using Teledyne LeCroy's flexible and deep analysis toolbox.

Main Specifications

Bandwidth 4 GHz - 30 GHz
Starting from $75,600
Standard Memory 20 Mpts - 768 Mpts
Max Memory 768 Mpts/Ch
Max Sampling Rate 120 GS/s
Input Channels 4
Resolution 8-bit

 

 

 

Description
45 GHz Real-Time Bandwidth

Teledyne LeCroy has again broken bandwidth barriers by utilizing widely adopted and proven SiGe processes, custom 2nd generation ASIC designs, and 6th generation Digital Bandwidth Interleave (DBI) technology to achieve unprecedented real-time oscilloscope performance:

  • 45 GHz
  • 120 GS/s
  • 768 Mpts/Ch Analysis Memory

 

20 GHz/4ch Model

Four channel performance at 20 GHz is pristine with exceptional rise time, overshoot, total and random jitter noise floor, and electrical noise performance.

Teledyne LeCroy — The Analysis Memory Leader

Teledyne LeCroy has found a way to make long acquisition memory seamless and pain free to use. The WaveMaster 8 Zi-A Series' proprietary X-Stream II architecture supports capturing, zooming, measuring and analyzing multiple waveforms at up to 768 Mpts deep. WaveMaster 8 Zi-A's proprietary architecture design is augmented with an Intel® Core™ 2 Quad processor (12 GHz effective clock rate), high-speed serial data buses, Windows 7 64-bit OS and 8 GB of RAM. What you experience is processing speed 10-100x faster compared to other oscilloscopes in this class.

Highest Stability Timebase and Lowest Jitter Noise Floor

An exceptionally accurate and stable time base is incorporated for the best possible jitter measurement accuracy jitter noise floor is as low as 125 fsrms. Teledyne LeCroy provides highly stable measurements at full (768 Mpts) record lengths, simplifying debug of low frequency events.

Freedom from Probing Limitations

High bandwidth differential probes (up to 25 GHz), single-ended active probes, current probes, high-voltage, and mixed signals all connect to the WaveMaster 8 Zi-A oscilloscope and give you a total system view. All WaveMaster 8 Zi-A oscilloscopes contain selectable 50 Ohm and 1 MOhm input capability and can be used with any Teledyne LeCroy probe - passive or active - without requiring external adapters or power supplies.

 

Specifications & Detail
Data Sheet & Downloads